Home > Products > Level Measurement > Ultrasonic Level Transmitter 
Ultrasonic Level Transmitter

Ultrasonic Level Transmitter for Reservoirs , Chemical Storage Tanks , Sumps and Lagoons

Level Monitor
 Transmitt
  Control
Password Porotected

General Specifications:

Accuracy: ±0.25% of Range or 2 mm,whichever is greater
Display:  4 Large digit LCD
Power Input: 100-130VAC
IP 66
Calibration:Selectable Level/Range mode


  Brochure  

  User's Guide

  Order Form

  Dimension

 

 

 

IMC 350  Level Indicating Transmitter

- LowCost
- Isolated 4-20mA Output from sensor & Converter
- RS 232 or RS 485 output
- Large LCD Display
- Programmable 2 Signal Relays(optional 6 Relays)

- Built-in 3-Key Calibrator
- Watertight, Dust tight Enclosure
- Self Testing
- Non Contacting Ultrasonic Sensor
- Data Logger with PC software

 IMC 350 II  for 0... 6 meters.                                                                                                                                          

IMC 350 II , displays, controls ,transmits and log level.
Mount the non-contacting ultrasonic sensor at the top of your tank and the compact, watertight electronics/display enclosure at a convenient location nearby. Operators can calibrate the sensor with its 2-button Keypad.
Use the built-in relay for level control or alarm, the large 4-digit display for local indication, and the isolated 4-20mA output to to transmit level to a PLC.
The standard ultrasonic Sensor measures liquid levels up to 6 m

Brochure  

User's Guide

Order Form

                 

                                                                                             

LIT25 Level Indicating Transmitter

- LowCost
- Isolated 4-20mA Output (1000 ohm)
- Large LCD Display
- Programmable Signal Relay

- Built-in 2-Key Calibrator
- Watertight, Dust tight Enclosure
- Self Testing
- Non Contacting Ultrasonic Sensor(Optional PressureSensor)       

 LIT 25   for 0... 10 meter , Optional 15.6 m                                                                     . 

LIT 25 displays, controls and transmits level. Mount the non-contacting ultrasonic sensor at the top of your tank and the compact, watertight electronics/display enclosure at a convenient location nearby. Operators can calibrate the LIT25 with its 2-button Keypad, without climbing the tank. Use the built-in relay for level control or alarm, the large 4-digit display for local indication, and the isolated 4-20mA output to to transmit level to a PLC.

The standard ultrasonic Sensor measures liquid levels up to 32 ft. (10 m), and includes automatic temperature compensation. Choose the optional all-Teflon sensor for chemical compatibility, or one rated to 50 ft (15.6 m) range. All ultrasonic sensors are available with optional intrinsic safety for installation in hazardous rated locations. The LIT25 can also be ordered with gauge-type pressure sensors for special applications.

  Brochure

  User's Guide

  Order Form

 

 

 

 

DLT 2.0 Differential Level Transmitter 

- Measures Level, Differential Level and Open Channel Flow
- Two Non-Contacting Ultrasonic Sensors
- Large White Backlit LCD Display
- Three Isolated 4-20mA Outputs
- Built-in 5-Key Calibratior
-
2 Programmable Control Relays
-
Optional 2 Million Point Data Logger
- Optional Intrinsically Safe Sensors

DLT 2.0 for 0... 10 meter , Optional 15.6 meter

Reduce costs and simplify instrumentation at treatment plant headworks. The DLT 2.0 can measure both differential level plus flow through a flume. Install one Sensor on each side of a mechanical barscreen to continuously monitor, transmit and control level. Use the built-in control relays or 4-20mA outputs to automatically activate the barscreen rake at preset levels.

The DLT 2.0 is a simple solution for barscreen level control at wastewater treatment plants, pump stations and combined sewer systems. It includes two non-contacting ultrasonic sensors to measure level. With sensors positioned above a channel, up and downstream from the barscreen, the DLT 2.0 can display and transmit differential level. The downstream sensor can also be installed above a flume or weir to measure and totalize open channel flow.

Three 4-20mA outputs are configured to transmit upstream level, downstream level (or flow) and differential level. Built-in relays can be calibrated for level control, differential level control or open channel flow.

 

Other DLT 2.0 applications include two-tank inventory where you can monitor level in two tanks with one instrument. The DLT 2.0 will alternate display of level in both tanks plus transmit 4-20mA outputs. Use the built-in relays to activate alarms or level controls. This versatile dual-sensor instrument can also be configured as a submergence alarm for Parshall flumes

 

:Partners
Flow-Tronic , Belgium
Pulsar , UK
SAIV A/S, Norway
Isoil Industria, Italy
Toscano , Spain
Micronics , UK
Aqualabo,France

Activates:
Non-Contact Radar Flow Measurement
Electromagnetic Flowmeters
Ultrasonic Flowmeters(Transit time)
Ultrasonic Flowmeters( Doppler )
Open Channel Measurement
Level Measurement
Pressure Measurement /Pressure Logger
Ultrasond Alga Cleaner

:About Us
Company Profile
Views & goal
Standards & Certifications
Seminars & Conferences

Exhibitions
Required order Forms

:Contact Us
Address and Map
Phone numbers
Send email
Site Map
Request representation


Privacy Policy/Copyright@ 2017-2018 AB SANJ MEHR All rights reserved.